Repsol YBF
Amazon Basin – Block 16 Development Project
Ecuador

Indirect Fired Water Bath Heater for Crude Oil Heating.

The scope of works included the supply and manufacture of one Off Indirect Fired Bath Heater for Crude Oil Heating in accordance with client’s drawings and specifications and in line with internationally recognised standards and procedures for quality and manufacturing.

The Indirect Fired Water Bath Heater had dimensions of 6000mm length x 1600mm diameter and was skid mounted complete with stack, burner box, coil and firetube installed inclusive of the mounting of all major equipment supplied by the client and all associated piping, conduit, wiring, instruments, valves, controls, necessary walkways, platforms, stairs, ladders, and minor equipment not furnished by the client.

The full assembly including all fuel gas pipework & drain pipework was supplied tested and painted to client specification.

Technical Specifications:-

1) Skid base was 305 x 168 x 46 Kg/M c/w 2 earth bosses and one main x-bracing between supports.
2) Sole plate included with s/s and PTFE.

3) Coil provided with ASME Section VIII Division 1 U-Stamp manufactured from Coil Pipe Schedule 80.